B, Sector-4, Dwarka, New Delhi Support +91-8800334308
Security & Access Design

Automatic Door
System Design

Automatic door system design for commercial, hospitality, healthcare and high-security buildings — sliding, swing, revolving, speed gate and turnstile design with access control integration and BS EN 16005 safety compliance.

Get a Free Quote WhatsApp Us

What We Offer

Automatic door systems are the physical interface between building security and occupant convenience. The right automatic door solution improves pedestrian flow, enforces access control, reduces energy loss through vestibules and creates a professional building entrance experience. ASDV Consultant designs automatic door systems for all building types and security requirements.

Our designs cover the full range of automatic door technologies: sliding doors (single/bi-parting) for retail, hospitals and lobbies; swing doors for accessible entrances; revolving doors and automatic revolving doors for high-traffic energy-efficient entrances; speed gates and optical turnstiles for office buildings requiring secure pedestrian access control; full-height turnstiles for high-security and industrial sites; and mantrap/airlock portals for data centres and critical facilities.

Every automatic door design integrates with the building's access control system — defining credential readers, intercom interfaces, door controller connections and fire alarm release modes. We design to BS EN 16005 (pedestrian power operated door sets) for safety and ISO 21542 for accessibility.

BS EN 16005
Safety Compliant
All Types
Sliding/Revolving/Gate
ACS
Integrated

Why Choose ASDV?

  • Certified ELV design consultants with 10+ years experience
  • AutoCAD & Revit BIM deliverables for seamless coordination
  • Full compliance with Indian & international standards
  • Transparent pricing with detailed BOQ and specifications
  • Pan-India service with international project capability

Design Deliverables

Door Type & Location Layout

Building entrance and internal door location plans showing door types, clear openings, vestibule dimensions and pedestrian flow directions.

Access Control Integration

Reader positions, controller interfaces, intercom connections and fire alarm release mode for each door.

System Architecture

Door controller topology, access control integration and centralized management platform.

Bill of Quantities

Itemised door operators, sensors, controllers, readers and accessories.

Technical Specifications

Door operator specifications covering drive type, opening speed, safety sensor requirements and access control interface.

Safety & Accessibility Compliance

BS EN 16005 safety compliance matrix and ISO 21542 accessibility requirements documentation.

What's Included

Automatic sliding door design (single/biparting)
Automatic swing door and low-energy opener design
Revolving door and automatic revolving door design
Speed gate and optical turnstile design
Full-height turnstile (tripod and full-height) design
Mantrap and security airlock design
Access control reader and intercom integration
Fire alarm release mode design (fail-safe/fail-secure)
Pedestrian flow analysis and door count design
Vestibule and lobby layout optimisation
BS EN 16005 safety sensor specification
Accessible entrance design (ISO 21542 / IS 1890)

Our Design Process

Traffic Analysis

Analyse pedestrian flow volumes, peak usage periods and security requirements to determine door type, count and speed.

Door Technology Selection

Select appropriate door type for each entrance based on security level, flow volume, energy performance and aesthetic requirements.

Layout & Dimensions Design

Design door clear opening widths, vestibule dimensions, sensor zones, safety edges and pedestrian flow paths.

Access Control Integration

Define credential reader positions, controller interfaces, intercom locations and fire alarm release modes for each door.

BOQ & Specifications

Produce itemised BOQ and technical specifications including safety and accessibility compliance requirements.

Installation & Commissioning

Review contractor submittals, witness safety sensor testing and access control integration commissioning.

Standards & Codes We Design To

BS EN 16005 (Automatic Doors)
ISO 21542 (Accessibility)
EN 60335-2-103 (Safety)
EN 13241 (Industrial Doors)
IS 1890 (Accessibility India)
NBC India 2016
BS 7036 (Automatic Doors)
IEC 60839 (Access Control)

Frequently Asked Questions

Commercial offices typically use: automatic sliding doors for main lobbies (high traffic, good energy performance), speed gates or optical turnstiles for controlled access between lobby and office floors (medium security, high flow rate), and swing doors with low-energy automatic openers for accessible entrances and internal fire doors. High-security offices may use mantrap portals at server room or data centre entries.

A speed gate uses retractable glass or acrylic wings that swing open rapidly when authorised credentials are presented — allowing passage in under 0.5 seconds and handling 30–40 people per minute. Speed gates are designed for office lobbies requiring controlled access with a prestigious appearance. Full-height turnstiles use rotating arms that allow only one person per credential presentation and provide physical anti-tailgating protection — used in higher security or industrial environments.

Automatic doors on evacuation routes must fail-safe (fail-open) on fire alarm activation to ensure free egress. Magnetically held-open fire doors must fail-closed (fail-secure) to contain fire and smoke spread. The design defines each door's fail mode based on its position on an evacuation route and its fire door/smoke door designation. These interfaces are documented in the fire alarm Cause & Effect matrix.

Need an Automatic Door System Design?

Contact ASDV Consultant for a complete automatic door design with access control integration, BOQ and BS EN 16005 compliance.